The XzTKMXpw 50x4x0.8 (TC0030) telecommunication cable is a durable and reliable solution designed for professional data transmission and telecommunication signal installations. Its construction, based on 200 conductors with a 0.8 mm² cross-section, ensures stable operating parameters and high transmission capacity, making it suitable for companies, institutions, and facilities that require dependable, long-term connectivity.
The cable features a black outer sheath resistant to standard operating conditions while maintaining a clean and functional appearance. Its approximate outer diameter of 30 mm allows convenient routing in trays, ducts, and telecommunications cabinets. The product is not intended for direct burial, which means it is best used in indoor installations or protected technical pathways.
Safety-related parameters indicate that the cable has no assigned classes for fire reaction, smoke emission, acidity, or flaming particles according to EN 13501-6. This signifies a lack of classification rather than non-compliance, and implies suitability for standard installation environments where such categorization is not required.
The sales unit is 1 meter, with a weight of 1.4 kg per meter. Logistical dimensions for one unit are 1 m × 0.03 m × 0.03 m, with a volume of 0.001 m³. The product is classified under customs code 85444993.
Overall, the XzTKMXpw 50x4x0.8 cable is a robust telecommunication conductor offering reliable data transmission and stable performance. With its solid construction, large number of conductors, and careful manufacturing, it is well suited for professional installations requiring durability and quality.
Construction and Physical Parameters
Number of conductors: 200 (50 pairs × 4 wires × 0.8 mm²)
Nominal conductor cross-section: 0.8 mm²
Approximate outer diameter: ~30 mm
Sheath color: Black
Sales unit: 1 m
Weight: 1.4 kg/m
Logistical dimensions (L/W/H/volume): 1 m / 0.03 m / 0.03 m / 0.001 m³
Customs code: 85444993
Functional Properties
Suitable for direct burial: No
Applications: Telecommunication installations, signal transmission, data transfer, internal systems
EN 13501-6 Classification
Smoke emission: None
Acidity: None
Reaction to fire: None
Flaming droplets/particles: None
We have made every effort to ensure that the above data is correct, but we do not guarantee that the published information does not contain errors, which, however, cannot constitute the basis for any claims.