The sealing clips TDUX-CL are part of a cable duct sealing system used in combination with the TDUX sleeve when the sewer pipes contain more than two cables. To seal three or more cables in the duct, you need to calculate the effective diameter of the cable bundle. To determine the maximum diameter of the cable bundle, subtract 5 mm from the maximum cable diameter given in the clip selection table for each clip used. One TDUX-CL clip can seal up to four cables. If more cables are installed in the duct, one additional clip should be used for every three additional cables. TDUX-CL clips are not compatible with TDUX-35 size seals. These clips are only suitable for use with TDUX-45 seals and larger. The TDUX-35 seal is only suitable for sealing empty ducts or ducts containing one cable. TDUX-CL clips should be ordered as separate items.
|